Section 9 - Maintenance Schedule
INTERVAL ACTION
Periodically/Daily - 8 hours maximum
Monitor all gauges and indicators for normal operation.
Check fluid level.
Observe for fluid leaks.
Observe for unusual noise or vibration.
Drain water from air/fluid reservoir.
Weekly Check pressure relief valve operation.
Monthly
Service inlet filter as needed (daily or weekly if extreme
conditions exist).
Clean fluid cooler fins.
Wipe entire unit down to maintain appearance.
6 months or every 1000 hours Change fluid filter and fluid strainer.
Periodically/yearly
Go over unit and check all bolts for tightness.
Change air/fluid separator element.
Change inlet filter element.
Lubricate motors.
Check safety shutdown system.
Contact a qualified serviceman.
Check pressure relief valve for pressure setting.
Every two years Change cooler hoses.