Installation manual

RIVA PLUS MANUAL 27
12. Electrical Connections/Wiring Cont.
11.3 Room Thermostat Connection:
The room thermostat must be connected
to the terminal block situated next to the
control panel.
Figure 11.6
Any external controls and connection
lines must be rated at 120 VAC but un-
der no circumstances should external live
voltage be connected to the room thermo-
stat link on the boiler.
11.4 Relay Panel Connection:
When connecting any type of external
control, the jumper J in Fig. 12.6 must be
removed.
The room thermostat must be connected
to the “Control Terminal Block” (Fig 12.7).
Figure 11.7
Connect the room thermostat between
terminals 1 and 3 as shown in Fig. 12.7.
The relay control must be connected to
the terminal block situated next to the
control panel.
Figure 11.8
When connecting any type of relay con-
trol, the jumper J in Fig. 12.8 must be re-
moved.
Connect the dry contact switch of the re-
lay panel to the 120 VAC control terminal
block (Fig 12.9).
Figure 11.9
Connect the dry contact switch to termi-
nals 1 and 3 shown in Fig. 12.9.