Product Manual
Table Of Contents
QP Series Quincy Compressor
2022201802, July 2014 11 3501 Wismann Lane, Quincy Ill. - 62305-3116
Fig. 3-2
Single Phase Magnetic Motor Starter With Automatic Start / Stop Control
Wiring Schematic WP1744B (Rev. D)
Magnetic Starter
Contactor
Overload
Relay
Connect incoming power lines
at screw terminals L1 & L2.
CAUTION !
Verify all wires are secure
and fasteners are torqued
before connecting power to
the unit.
All wires are red unless otherwise speciîżed.
Dashed lines represent wires supplied by others.
At Installation, the customer is to provide:
Disconnect and branch circuit overcurrent protection and grounding
between the power supply and the electrical control enclosure in accor-
dance with the National Electrical Code (NEC), the Canadian Electrical
Code (CEC) and / or any local codes having precedence.