Product Manual

ENGLISH
Cod. 9828093309 00 - Edition 05/2019 - 15
TYPE
DRYER
Weight
Kg.
R 134a
Kg.
Nominal
Power W
bar
MAX.
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
A1
19
0,170
0,170
135
125
29
42
164
172
bar 16
A2
20
0,290
0,290
161
173
29
49
190
222
bar 16
A3
25
0,350
0,350
233
252
33
54
266
306
bar 16
Reference conditions:
Ambient temperature 25 °C
Inlet air temperature 35 °C
Pressure 7 bar
Dew point in pressure 3 °C
Limit conditions:
Max. ambient temperature 45°C
Min. ambient temperature 5°C
Max. inlet air temperature 55°C
Max. working pressure 16 bar
14.0 MACHINE ILLUSTRATION
14.1 GENERAL LAY-OUT FOR DRYER AND TANK
1 Refrigerant compressor
2 Condenser
3 Motor fan
4 Evaporator
5 Condensate drain solenoid valve
6 Hot gas bypass valve
7 Refrigerant filter
8 Expansion capillary tube
9 Safety valve (Compressed air tank)
10 Compressed air tank
11 Condensate manual drainage
IT IS FORBIDDEN TO TAMPERE WITH THE
SETTING VALUES OF THE SAFETY VALVE
Nominal
Power W
Nominal
Power W
10
9
10
11
1
2
3
4
5
6
7
8
FIG. 14
11