Product Manual
ENGLISH
22 - Edition 05/2019 Cod. 9828093309 00 -
15.6 CHECKING THE AUTOMATIC AND MANUAL CONDENSATION EMPTYING (FOR DRYER AND
TANK)
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND
DISCONNECT IT FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION
NETWORK.
The automatic and manual condensation drain (Rif. 8 and Ref. 11 Fig. 19) must be checked every day.
Proceed as follows:
- Press the "TEST" button, Ref. 8 Fig. 19, for a few seconds to check if the condensation is correctly emptied from the
drainage pipe
- Check manual condensation emptying from the tank, to ensure that condensation is correctly emptied from the valve,
Ref. 11 Fig. 19 (PURGE EVERY DAY).
15.7 CLEANING THE CONDENSER BATTERY (FOR DRYER )
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND
DISCONNECT IT FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION
NETWORK.
The condenser must be cleaned every month (Ref. 6 Fig. 19).
Proceed as follows:
- Stop the machine, (See pag. 17).
- Press the button switch Rif. 2 Fig. 19 (on the dryer if fitted)
- Turn on the differential supply switch, Ref. 3 (on the screw-compressor) and Ref. 4 (on the dryer if fitted) Fig. 19.
HOT PARTS INSIDE
- Remove the protection Ref. 5 Fig. 19
- Clean the condenser fins Ref. 6 Fig. 19 with compressed air (see Fig. A). DO NOT USE WATER OR SOLVENTS.
- Close the protection Ref. 5 Fig. 19.
15.8 CLEAN THE DIRT COLLECTION FILTER FOR DRYER (Ref. 9 - 10 Fig. 19)
BEFORE CARRYING OUT ANY MAINTENANCE IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT
IT FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
Proceed as follows:
- Close the tap Ref. 7 Fig. 19
FIG. 19
3
4
2
6
5
10
9
8
7
5
11