Product Manual
ENGLISH
28 - Edition 05/2019 Cod. 9828093309 00 -
20.2 PRELIMINARY CHECKS
Check the oil level Ref. 1 Fig. 23; when delivered the machine is filled with oil; if the oil level is not as intended, top up
with the same oil as the original type.
If more than 3 months have passed between the inspection in the factory and the date of installation, lubricate the
screw group before starting up, following the procedure described below:
- Remove the protection Ref. 2 Fig. 23
- Remove the fixed protection device (machine cover) Ref. 3 Fig. 23.
- Remove the cover Ref. 4 Fig. 23
- Remove the air filter Ref. 5 Fig. 23
- Pour a little oil into the suction unit.
- Reassemble the air filter Ref. 5 Fig. 23
- Reassemble the cover Ref. 4 Fig. 23
If more than 6 months have passed between the inspection in the factory and the date of installation, consul
the manufacturer.
20.3 STARTING THE DRYER
Start the dryer before turning on the compressed air.
The compressed air piping will be free of condensate only by doing so.
The dryer must be kept running during all the time the air compressor is running. WARNING: if the dryer is switched off,
before starting it again, wait at least 5 minutes in order to allow the pressure balancing.
FIG. 23
DO NOT EXCEED THE
MAXIMUM LEVEL.
MAXIMUM LEVEL
WITH THE MACHINE
OFF
MINIMUM LEVEL
WITH THE MACHINE
OFF
1
5
4
Oil
3
2