20.4 CHECK THE COMPRESSOR ROTATION DIRECTION AND START UP
- Check that all the protective shields are in place.
- Apply voltage to the control panel by operating the automatic differential switch of the line Ref. 1 Fig. 24.
- Start the compressor by turning the selector to “ I ”, Ref. 2 Fig. 24 and after 1 second, stop it by turning the isolating
switch to “OFF” Ref. 2a Fig. 24.
- If the rotation is correct, the paper sheet Ref. 3 is blown up (See Fig. A)
- If the rotation is not correct, the paper sheet remains flat (See Fig. B) PHASE INCORRECT
ALL WORK ON THE ELECTRIC PLANT, HOWEVER SLIGHT, MUST BE CARRIED OUT BY
PROFESSIONALLY SKILLED PERSONNEL.
- Disconnect the energy supply and invert two connections as per Ref. 1 Fig. B.
IT IS ADVISABLE NOT TO DO ANYTHING ON THE MACHINE PANEL.
IF ALL THE INSTRUCTIONS FOUND IN THIS MANUAL HAVE BEEN OBSERVED THE MACHINE CAN BE
STARTED.
21.0 GENERAL ORDINARY MAINTENANCE REQUIRES TRAINED PERSONNEL
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND
DISCONNECT IT FROM THE POWER MAINS.
MAINTENANCE SCHEDULE
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated. For
particularly dusty environments, double the frequency of controls.
Every Day (after use)
◼ Drain condensate from the air tank
◼ Check automatic condensation emptying (dryer)
Every 50 working hours
◼ Drain condensate from the oil tank
◼ Check the oil level
◼ Clean the filtering panel
Every 500 hours
◼ Clean the air suction filter
◼ Clean the condenser battery (on the dryer if fitted)
◼ Clean the dirt collection filter (dryer)
◼◼ Check belt tension
Every 2000 hours
◼ Change the suction filter
◼◼ Change the oil
◼◼ Change the oil filter
Every 4000 hours
◼◼ Clean the finned surface of the air-oil cooler
◼◼ Change the oil separating filter
N.B.: THE OPERATIONS MARKED ◼ ARE DESCRIBED IN PART "A" OF THIS MANUAL ON CHAPTER 15.1
These cables are part of
the machine l~ 4 meters
FIG. 24
Protect the power cable with a suitable channel.
PHASE INCORRECT
2
3
1
OK
FIG. A
2a
a
1
FIG. B