Data Sheet

X
Ab.
.
a. Measured at the discharge terminal point of the compressor package in accordance with
ISO 1217, Annex C; ACFM is actual cubic feet per minute at inlet conditions.
b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 11) were measured
for this data sheet.
c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the
maximum pressure attainable before capacity control begins. May require additional power.
d. Total package input power at other than reported operating points will vary with control strategy.
e. Tolerance is specified in ISO 1217, Annex C, as shown in table below:
NOTE: The terms "power" and "energy" are synonymous for purposes of this document.
m3 / min
Below 0.5
0.5 to 1.5
1.5 to 15
Above 15
X
A.
1
2
COMPRESSOR DATA SHEET
In Accordance with Federal Uniform Test Method for Certain Lubricated Air Compressors
Rotary Compressor: Fixed Speed
MODEL DATA - FOR COMPRESSED AIR
Manufacturer:
Model Number: Date:
Type:
# of Stages:
Rated Capacity at Full Load Operating Pressure
Full Load Operating Pressure
Maximum Full Flow Operating Pressure
3*
4*
5
6
7
8
9
10*
11
12*
13
Drive Motor Nominal Rating
Drive Motor Nominal Efficiency
Fan Motor Nominal Rating (if applicable)
Fan Motor Nominal Efficiency
Total Package Input Power at Zero Flow
Total Package Input Power at Rated Capacity and Full Load Operating
Pressure
Package Specific Power at Rated Capacity and Full Load Operating
Pressure
Isentropic Efficiency
acfm
psig
psig
hp
percent
kW
kW
kW/100 cfm
Percent
hp
percent
*For models that are tested in the CAGI Performance Verification Program, these items are verified by the third party administrator.
Consult CAGI website for a list of participants in the third party verification program:
NOTES:
ft3 / min
Below 17.6
17.6 to 53
53 to 529.7
Above 529.7
%
+/- 7
+/- 6
+/- 5
+/- 4
No Load / Zero
Flow Power
Volume Flow Rate at
specified conditions
Specific Energy
Consumption
+/-10%
Quincy Compressor
A.
QGS-50C
A.
Screw
A.
1
A.
1/15/2021
Ab.
.
203.2
125
50
9.7
45.1
67.6
Volume Flow Rate
%
+/- 8
+/-7
+/-6
+/-5
ROT 030.1
12/19 Rev 3 This form was developed by the Compressed Air and Gas Institute for the use of its members participating in the PVP. CAGI has not independently verified the reported data.
Member
www.cagi.org
Air-Cooled Water-cooled
NA
A.
%
Oil-injected Oil-free