Product Manual
Page | 6
WIRING
STARTING THE COMPRESSOR
Prior to actually running the compressor, check
the following items:
Crankcase oil - Make sure the sight glass
shows 1/2 full or slightly above.
Make sure all rags, tools, oil, etc. are away
from the unit.
Open the air system to free it of any pressure.
Switch the compressor on for a few revolutions
to make sure the rotation is correct. Correct
rotation is clockwise when facing the sight
glass on the pump.
Operate the compressor for a few minutes
unloaded (air system open) then allow the
compressor to pump up. Make sure the
electrical pressure switch properly switches off
the compressor according to the setting
desired. 145 psi - Single Stage or 165 psi.
Make sure the pressure in the tank does not
exceed its rating. Single Stage units - 145 psi
If the pressure gauge indicates a pressure that
is higher than these maximum pressures, shut
off compressor immediately and call your
distributor.
CAUTION
1 PHASE START/STOP CONTROL
WIRING SCHEMATIC
CIRCUIT
BREAKER
DISCONNECT
AUTO
OFF
PRESSURE
SWITCH
OPTIONAL
COIL
AUX.
LOW OIL
LEVEL SWITCH
OL
MOTOR