Installation Guide

Connect the Q35 to a network with an Ethernet cable using the RJ-45 Ethernet socket. For your safety
and to prevent any damage to the device, only connect the Q35 to standard certified network
components.
When the Q35 is properly connected to the network, but not activated by the QPE software, the red
indicator light blinks slowly. The blue indicator light flashes or is statically lit when the Q35 is activated by
the QPE software. If needed, it is possible to turn the Locator’s indicator light LED off when in tracking
mode. For more information, please see separate instructions.
The table below shows the different Locator modes as indicated by the Locator’s indicator light.
Colour Sequence
Sequence Description
Indicator Light Mode
Flash red - green - blue once
Reboot sequence
Static red
Locator powered, no IP address
Flashing red
Locator connected to network
Static blue
Locator in tracking mode
Flashing blue
Locator in deployment mode
Flashing white
Locator firmware upgrade in progress
Flash red twice, pause and repeat
Locator subscription not valid
LED off
Optional indicator light state for
tracking mode
ESD Precautions
To prevent damage to the device caused by electrostatic discharge (ESD) during the installation process,
please follow the recommendations listed below.
Use shielded Ethernet cables.
Use the connector provided in the product box to attach the cables and avoid touching the
signal cable directly.