User's Manual
Table Of Contents
- Federal Communication Commission (FCC) Compliance
- Industry Canada Compliance
- Overview
- Intended Audience
- Additional Detailed Documentation
- Contact Information
- Product Warranty
- Chapter 1
- Introduction
- Central Server and Client Computers
- 9450 System
- Exit Alarm Controller
- Card Reader Access Device
- The Exit Alarm Zone
- Exit Alarm Receiver
- Magnetic Reed Switch
- CodeLock Electromagnetic Lock
- Alarming Band Receivers
- Alarming Band Zone
- Quick Look Display
- Transmitters
- Wander Management Transmitter
- Alarming Band Transmitters
- Mother Transmitter
- 9600 QR System
- Gateway
- Router
- Universal Transceiver
- Pendant Transceivers
- Pull-Cords
- Check-in Pull Cord
- Nurse Call
- Smoke Detector
- Asset Transceiver
- Door/Window Transceivers
- Reset Button
- Fall Management Systems
- Sensor Pads
- Using the Fall Management System
- Pagers and Walkie-Talkies
- Event Paging
- Pager Delays, Retries and Escalation
- Walkie-Talkie System
- Chapter 2
- Introductions
- Start the Software
- Window Conventions
- Touchscreen Monitor
- Map Orientation
- Ruleset for Displaying Patient Name
- The Main Window
- The Menu Bar
- Monitor
- Tools
- Paging
- Asset
- Help
- Top Toolbar
- Bottom Toolbar
- Low Battery Icon
- Chapter 3
- Introduction
- Commonly Used Terms
- Login and Passwords
- Units
- Supervised Transmitters
- Global Lockdown
- Common Operations
- Admit
- Patient Admit Information Window
- Asset Admit Information Window
- Discharge
- Escort
- Transfer
- Adjust
- Reports
- Silence
- Chapter 4
- Introduction
- Events
- Devices Displayed on the Map
- Devices Assigned to a Room
- Event Types
- Event Information Window
- Event Information Window Properties
- Red Alarms
- Door Alarm
- Exit Alarm (Wide Gap)
- Smoke Alarm
- Perimeter Alarm
- Cut Band Alarm
- Mismatch Alarm
- Match Alarm
- Link Alarm
- Check Alarm
- Check Transmitter Alarm
- Assistance Required
- Server Missing
- Yellow Alarms
- Client Missing
- Device Fault
- Low Battery
- Blue Alarms
- Door Alarm
- Cut Band Alarm
- Check Transmitter Alarm
- White and Light Blue Alarms
- Auto-enroll (White Alarm only)
- Escort to Expire
- Escort Expired
- Transfer to Expire
- Transfer Expired
- Discharge Expired
- Adjust Expired (White Alarm only)
- Begin Adjust (White Alarm only)
- Admit Complete
- Discharge Complete
- Escort Complete
- Transfer Complete
- Adjust Compete (White Alarm only)
- Chapter 5
- Introduction
- Reports
- Viewing a Report
- Reports Toolbar
- System Reports
- Response Time
- Activities Report
- Alarm Report
- Alarm Response Report
- All Activities Report
- JCAHO Report
- JCAHO Assistance Report
- Alarm Activities Report
- Census Report
- Auto Enrolled History Report
- Adjusted Bands Report
- Transfer Report
- Escort Report
- Discharge Report
- Staff Drill Report
- System Maintenance Report
- Low Batteries Report
- Device Fault Report
- Device Hardware Report
- Transmitter Report
- Users Report
- Training Report
- User Training Report
- All Other Reasons Report
- Links Report
- Links Activities Report
- Patient Reports
- Review Info Report
- Review Activity Report
- Review Response Report
- Asset Reports
- Asset Transmitter Report
- Asset Activities Report
Chapter 4: Handling Events
82 Series 5.0 Software (0510-1059-A_DRAFT) - User Guide
White and Light Blue Alarms
The following sections provide detailed information about White and Light Blue Alarms, responding to alarming
events, and the way the event should be cleared. White Alarms are patient generated alarms; Light Blue Alarms
asset generated alarms.
Auto-enroll (White Alarm only)
The Auto-Enroll feature automatically enrolls alarming band transmitters into the system without requiring a
manual admit. Once the transmitter is auto-enrolled, the system monitors the transmitter for Door, Cut Bands,
or Check-In alarms.
To respond to an Auto-Enroll
1. From the Client computer (s), click anywhere in the Auto-Enroll Alarm Message Box to access the
Event Information window.
2. Select one of the followings:
• Clear—clears the Auto-Enroll from the Alarm Message Box and the Event List.
• Admit—opens the Admit Information window for that transmitter so that you can assign the
transmitter to a patient.
• Close—closes the Admit Information window without clearings the Auto-Enroll.
Escort to Expire
This alarm occurs when the time allowed for a patient or asset to be escorted will expire in 15-minutes. The
alarming band transmitter, in the Escort mode, has not been moved from or has not yet been returned to the
protected area.
To respond to an Escort to Expire
1. Determine the location of the patient or asset.
2. If the patient or asset is secure and will not be returned to the protected area soon, clear the Escort to
Expire alarm and extend the Escort function.
3. If the patient or asset has not yet been moved, clear the Escort to Expire alarm and cancel the escort.