User's Manual
Table Of Contents
- Federal Communication Commission (FCC) Compliance
- Industry Canada Compliance
- Overview
- Intended Audience
- Additional Detailed Documentation
- Contact Information
- Product Warranty
- Chapter 1
- Introduction
- Central Server and Client Computers
- 9450 System
- Exit Alarm Controller
- Card Reader Access Device
- The Exit Alarm Zone
- Exit Alarm Receiver
- Magnetic Reed Switch
- CodeLock Electromagnetic Lock
- Alarming Band Receivers
- Alarming Band Zone
- Quick Look Display
- Transmitters
- Wander Management Transmitter
- Alarming Band Transmitters
- Mother Transmitter
- 9600 QR System
- Gateway
- Router
- Universal Transceiver
- Pendant Transceivers
- Pull-Cords
- Check-in Pull Cord
- Nurse Call
- Smoke Detector
- Asset Transceiver
- Door/Window Transceivers
- Reset Button
- Fall Management Systems
- Sensor Pads
- Using the Fall Management System
- Pagers and Walkie-Talkies
- Event Paging
- Pager Delays, Retries and Escalation
- Walkie-Talkie System
- Chapter 2
- Introductions
- Start the Software
- Window Conventions
- Touchscreen Monitor
- Map Orientation
- Ruleset for Displaying Patient Name
- The Main Window
- The Menu Bar
- Monitor
- Tools
- Paging
- Asset
- Help
- Top Toolbar
- Bottom Toolbar
- Low Battery Icon
- Chapter 3
- Introduction
- Commonly Used Terms
- Login and Passwords
- Units
- Supervised Transmitters
- Global Lockdown
- Common Operations
- Admit
- Patient Admit Information Window
- Asset Admit Information Window
- Discharge
- Escort
- Transfer
- Adjust
- Reports
- Silence
- Chapter 4
- Introduction
- Events
- Devices Displayed on the Map
- Devices Assigned to a Room
- Event Types
- Event Information Window
- Event Information Window Properties
- Red Alarms
- Door Alarm
- Exit Alarm (Wide Gap)
- Smoke Alarm
- Perimeter Alarm
- Cut Band Alarm
- Mismatch Alarm
- Match Alarm
- Link Alarm
- Check Alarm
- Check Transmitter Alarm
- Assistance Required
- Server Missing
- Yellow Alarms
- Client Missing
- Device Fault
- Low Battery
- Blue Alarms
- Door Alarm
- Cut Band Alarm
- Check Transmitter Alarm
- White and Light Blue Alarms
- Auto-enroll (White Alarm only)
- Escort to Expire
- Escort Expired
- Transfer to Expire
- Transfer Expired
- Discharge Expired
- Adjust Expired (White Alarm only)
- Begin Adjust (White Alarm only)
- Admit Complete
- Discharge Complete
- Escort Complete
- Transfer Complete
- Adjust Compete (White Alarm only)
- Chapter 5
- Introduction
- Reports
- Viewing a Report
- Reports Toolbar
- System Reports
- Response Time
- Activities Report
- Alarm Report
- Alarm Response Report
- All Activities Report
- JCAHO Report
- JCAHO Assistance Report
- Alarm Activities Report
- Census Report
- Auto Enrolled History Report
- Adjusted Bands Report
- Transfer Report
- Escort Report
- Discharge Report
- Staff Drill Report
- System Maintenance Report
- Low Batteries Report
- Device Fault Report
- Device Hardware Report
- Transmitter Report
- Users Report
- Training Report
- User Training Report
- All Other Reasons Report
- Links Report
- Links Activities Report
- Patient Reports
- Review Info Report
- Review Activity Report
- Review Response Report
- Asset Reports
- Asset Transmitter Report
- Asset Activities Report
Chapter 1: Equipment Overview
10 Series 5.0 Software (0510-1059-A_DRAFT) - User Guide
Transmitters
Wander Management Transmitter
A Wander Management transmitter is a wireless, mobile transmitter
that can be worn around the wrist or ankle. An event is reported in the
Event list when a patient attempts to leave an Exit Zone.
Alarming Band Transmitters
Alarming band transmitters are placed on the ankle or wrist of a patient. The transmitter becomes active one
minute after the banding material is connected. The one-minute window exists to allow for re-adjustment of the
banding material.
After one minute, the transmitter ID is displayed in the Event List and information of the patient wearing the
transmitter can be associated with the transmitter using the Admit function. Alarming band transmitters can be
supervised; if no information is received by the system from the transmitter within the configured amount of
time, a Check alarm is generated in the Event List. For more information about securing, cleaning, and
troubleshooting transmitters, see the appropriate Transmitter User Guide.
Asset Tracking
Alarming band transmitters can be used for asset management. When an alarming band transmitter is attached to
an asset and admitted using the New Asset admit function, Blue alarms are generated and appear in the Event list
when an attempt is made to remove the assets from an Exit Zone or the band is tampered with or cut.
Infant Transmitter
Patient Transmitter