User's Manual
Table Of Contents
- Federal Communication Commission (FCC) Compliance
- Industry Canada Compliance
- Overview
- Intended Audience
- Additional Detailed Documentation
- Contact Information
- Product Warranty
- Chapter 1
- Introduction
- Central Server and Client Computers
- 9450 System
- Exit Alarm Controller
- Card Reader Access Device
- The Exit Alarm Zone
- Exit Alarm Receiver
- Magnetic Reed Switch
- CodeLock Electromagnetic Lock
- Alarming Band Receivers
- Alarming Band Zone
- Quick Look Display
- Transmitters
- Wander Management Transmitter
- Alarming Band Transmitters
- Mother Transmitter
- 9600 QR System
- Gateway
- Router
- Universal Transceiver
- Pendant Transceivers
- Pull-Cords
- Check-in Pull Cord
- Nurse Call
- Smoke Detector
- Asset Transceiver
- Door/Window Transceivers
- Reset Button
- Fall Management Systems
- Sensor Pads
- Using the Fall Management System
- Pagers and Walkie-Talkies
- Event Paging
- Pager Delays, Retries and Escalation
- Walkie-Talkie System
- Chapter 2
- Introductions
- Start the Software
- Window Conventions
- Touchscreen Monitor
- Map Orientation
- Ruleset for Displaying Patient Name
- The Main Window
- The Menu Bar
- Monitor
- Tools
- Paging
- Asset
- Help
- Top Toolbar
- Bottom Toolbar
- Low Battery Icon
- Chapter 3
- Introduction
- Commonly Used Terms
- Login and Passwords
- Units
- Supervised Transmitters
- Global Lockdown
- Common Operations
- Admit
- Patient Admit Information Window
- Asset Admit Information Window
- Discharge
- Escort
- Transfer
- Adjust
- Reports
- Silence
- Chapter 4
- Introduction
- Events
- Devices Displayed on the Map
- Devices Assigned to a Room
- Event Types
- Event Information Window
- Event Information Window Properties
- Red Alarms
- Door Alarm
- Exit Alarm (Wide Gap)
- Smoke Alarm
- Perimeter Alarm
- Cut Band Alarm
- Mismatch Alarm
- Match Alarm
- Link Alarm
- Check Alarm
- Check Transmitter Alarm
- Assistance Required
- Server Missing
- Yellow Alarms
- Client Missing
- Device Fault
- Low Battery
- Blue Alarms
- Door Alarm
- Cut Band Alarm
- Check Transmitter Alarm
- White and Light Blue Alarms
- Auto-enroll (White Alarm only)
- Escort to Expire
- Escort Expired
- Transfer to Expire
- Transfer Expired
- Discharge Expired
- Adjust Expired (White Alarm only)
- Begin Adjust (White Alarm only)
- Admit Complete
- Discharge Complete
- Escort Complete
- Transfer Complete
- Adjust Compete (White Alarm only)
- Chapter 5
- Introduction
- Reports
- Viewing a Report
- Reports Toolbar
- System Reports
- Response Time
- Activities Report
- Alarm Report
- Alarm Response Report
- All Activities Report
- JCAHO Report
- JCAHO Assistance Report
- Alarm Activities Report
- Census Report
- Auto Enrolled History Report
- Adjusted Bands Report
- Transfer Report
- Escort Report
- Discharge Report
- Staff Drill Report
- System Maintenance Report
- Low Batteries Report
- Device Fault Report
- Device Hardware Report
- Transmitter Report
- Users Report
- Training Report
- User Training Report
- All Other Reasons Report
- Links Report
- Links Activities Report
- Patient Reports
- Review Info Report
- Review Activity Report
- Review Response Report
- Asset Reports
- Asset Transmitter Report
- Asset Activities Report
Series 5.0 Software (0510-1059-A_DRAFT) - User Guide 85
Event Types
Adjust Expired (White Alarm only)
This alarm occurs when the selected amount of time required for the adjustment of the banding material has
expired and the adjustment has not been complete properly.
To respond to an Adjust Expired Alarm
1. Determine that the patient is secure.
2. If the banding material has not yet been adjusted, click anywhere in the Adjust Expired Alarm Message
Box to access the Event Information window.
3. Click Clear.
4. Perform the Adjust function again.
Begin Adjust (White Alarm only)
This alarm occurs after a configured amount of time to remind staff to check the alarming band transmitter for
band slippage. The time for the Require band slippage check is configured in the Configuration, Units menu (refer
to the Series 5.0 Software Administrator Guide).
To respond to an Adjust Alarm
1. Determine that the patient is secure.
2. Click anywhere in the Begin Adjust Alarm Message Box to access the Event Information window.
3. Click Clear.
4. If necessary, perform the Adjust function.
Admit Complete
This alarm occurs when the Admit function for a patient or asset is complete. This dialog box only appears if the
software has been configured to confirm the Admit.The Confirm Admit is configured in the Configuration,
Global Settings menu (refer to the Series 5.0 Software Administrator Guide).
Discharge Complete
This alarm occurs when the Discharge for a patient or asset is complete. This dialog box only appears if the
software has been configured to confirm the discharge.The Confirm Discharge is configured in the Configuration,
Global Settings menu (refer to the Series 5.0 Software Administrator Guide).