Owner`s manual
6
Real-Fyre gas burner systems must be installed only in a wood burning fi replace with the minimum fi rebox
dimensions and venting requirements met (see table on this page). This appliance is designed to burn with
yellow fl ames; adequate ventilation is absolutely necessary.
SPECIFICATIONS
The damper clamp with hex bolt (Fig. 6-2) is provided as a means to
prevent full closure of the damper blade. The clamp is easily attached to
most damper blades with pliers or a wrench, and must be permanently
installed. The clamp is designed to prevent accidental closure of the damper
when installed as illustrated (
Fig. 6-3 and Fig. 6-4). Should the clamp not
fi t, or fail to provide the permanent vent opening listed in the table found
above, have a permanent stop installed, remove
the damper blade, or have the damper cut to
provide the minimum permanent opening required.
Note: These are minimum damper opening
specifications. The damper must be
completely opened when operating
this gas appliance to achieve the best
ventilation possible.
Fig. 6-2
Damper clamp
Set screw
Fig. 6-3 Fig. 6-4
Open
Closed
PILOT
WIRE HARNESS
VALVE
OUTLET
ORANGE
BLUE
GREEN
INLET
AA-BATTERIIES (4)
BATTERY BOX
BATTERY-D
REMOTE
SYSTEM
CONTROL
MODULE
S
WIRE HARNESS
WIRES, OPTIONAL
WALL SWITCH
Wiring Diagram
Fig. 6-1
DAMPER CLAMP INSTRUCTIONS
(Remote model shown)
Burner
Model
Minimum Fireplace Size BTU Rating
Width
Depth Height Natural Gas Propane Gas
Front Rear
G22-GL-18(G)-01(M)(P) 27" 19" 13" 15" 40k 28k
G22-GL-24(G)-01(M)(P) 33" 25" 13" 15" 55k 40k
G22-GL-30(G)-01(M)(P) 39" 32" 13" 15" 65k 50k
Note: Rear width is at corresponding depth.
Note: The minimum chimney height from hearth to top of chimney is 15'.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fi replaces *
Chimney height 18" 24" 30"
15' 18 24 30
20' 15 21 25
30' 12 16 19
* For masonry-built fi replaces, add 5 sq. in. to amount shown