Owner`s manual

10
L-A2-376
Rev 0 - 1312261320
INSTALLATION (Cont.)
CONNECT TO A POWER SUPPLY
CAUTION: ENSURE THE UNIT IS CONNECTED TO
THE GAS LINE AND HAS BEEN TESTED
FOR LEAKS BEFORE YOU CONNECT TO
A POWER SUPPLY.
Locate the supplied power supply and connect it to the
ignition module pack, then route it to a GFCI 120VAC
receptacle (not included) as approriate for your setup.
Observe all codes. See Fig. 10-1.
INSTALL/REPLACE REMOTE TRANSMITTER
BATTERIES
CAUTION: ENSURE THE UNIT IS CONNECTED TO
THE GAS LINE AND HAS BEEN TESTED
FOR LEAKS BEFORE YOU INSERT
BATTERIES.
The remote transmitter requires 3 "AAA" batteries to
operate. Locate the transmitter, remove the lid (found
on rear), and properly insert new batteries as marked.
Re-secure the lid. See Fig. 10-2.
HEAT SHIELD PLACEMENT
Cover the valve with the heat shield as shown in Fig. 10-3
or Fig. 10-4.
It is critical that the heat shield be placed correctly
over the valve for the unit to operate properly. The
switch wire connecting the heat shield to the ignition
module pack is to be routed along the interior right
side of the heat shield. Keep all wires inside of the
heat shield and/or away from the fl ame. Keep the area
above the heat shield clear of decorative media or
any other object.
Important: Ensure the pilot supply tube does not
interfere with heat shield placement. For
2V models, the tube will come out of the
rear and coil back to the pilot. For 3V
models, the tube will come out of the left
side of the heatshield and coil to the pilot.
DECORATIVE MEDIA REPLACEMENT
Refer to the burner instructions for proper replacement
of decorative media.
Valve
heat shield
in place
Burner pan
Fig. 10-3 2V models: Place heat shield
Valve
heat shield
in place
Burner pan
Fig. 10-4 3V models: Place heat shield
Heat
shield
Heat
shield
Fig. 10-1 Connect cord to module / power supply
Fig. 10-2 Install/replace transmitter batteries
Remove
lid for
battery
access
To GFCI 120VAC
receptacle