Owner`s manual

2
REV 1 - 0711091249
No. L-A2-08107
CHECK TO BE SURE THAT THE SAFETY PILOT HAS BEEN ASSEMBLED FOR THE PROPER GAS.
(Reference FOR PROPANE GAS section on the next page.)
The installation, including provisions for combustion
and ventilation air, must conform with local codes, or,
in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 (latest edition).
This appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
when testing at pressures that exceed
1
/
2
psig. This is
accomplished by closing the gas supply line valve.
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any testing of the gas supply system at
test pressures up to and including
1
/
2
psig.
WHEN GLASS FIREPLACE ENCLOSURES
(DOORS) ARE USED, OPERATE THE GAS BURNER
WITH THE GLASS DOORS OPEN; BOTH SIDES IF
FIREPLACE IS SEE-THRU TYPE.
Gas inlet nipple
To gas
supply
To
nipple
CK-4
0
F
F
O
N
PILOT
9
8
7
1
3
4
5
6
10
2
Pilot gas supply line
Thermocouple lead
Supplied
with the
burner kit
Fig. 2-1
IMPORTANT INFORMATION
PARTS LIST
Item No. Part No. Description
1. SV-19 Safety control valve
2. PAC-1NAT Natural pilot assembly
or PAC-1LP Propane pilot assembly
3. HS-32 Heat shield
4. KNOB-6 SPK-26 knob
5. EH-2 Extension handle
6. SH-1 Flame diverter bracket
Item No. Part No. Description
7. PB-1 Pilot mounting bracket
8. GP-1 Pilot assembly insulation pad
9. PBO-20 Natural gas orifi ce
or PBO-10 Propane gas orifi ce
10. PT-1NAT Nat. pilot/thermocouple assy. w/leads
or PT-1LP LP pilot/thermocouple assy. w/leads