Owner`s manual

14
REV 4 - 0907131103
No. L-A2-01309
MAINTENANCE
Once installed and operating properly, the
Real-Fyre
®
gas log set requires very little
maintenance. You should inspect the log
set and control annually for the following:
1. Excessive Sooting - Some sooting of the
log set is normal and adds to the appearance
of burned wood. If sooting accumulates, you
may brush the soot off with a stiff brush. Do
not use water or soot cleaners to clean off
the soot.
2. Settling of Glowing Embers and granules
- Moisture may cause the granules and
Glowing Embers in the burner pan to settle
and affect the burn. Using a screwdriver or fl at
blade knife, you can carefully stir the granules
and embers, loosening the materials.
3. Debris around the control - Inspect the
control and pilot to be sure it is free of any
dirt or debris.
4.
Insects and burner blockage - Check the
burner ports and the air mixer, if present, to
make sure they are free from debris. Blocked
burner ports and orifi ces may result in poor fl ame
distribution or fl ame at air mixer (if equipped).
Reference SOLUTION, to symptoms 2-4, of
TROUBLESHOOTING.
SERVICE
While some minor service conditions may
be handled by the owner of the log set, it is
recommended that a qualified professional
service technician be called to service the gas
log set and control should service be required.
The TROUBLESHOOTING section of these
instructions serves as a guide for ensuring
optimum performance of the gas log set.
FLAME DESCRIPTION
Observe the fl ames. The fl ames should be blue at the
base and a combination of blue/yellow at the body
and tips. The fl ames should be 17" to 19" tall from
the fi replace fl oor.
If the Real-Fyre
®
gas log set is operated by
a Peterson remote safety pilot system (APK
series):
1. Light the pilot following the instructions
included with the remote safety pilot system.
2. Be sure the remote switch is in the OFF
position.
3. Turn the APK valve from the PILOT position
to the ON position (Fig. 14-1).
4. Turn the APK remote control switch to the ON
position. The log set should light.
5. If the log set fails to light, turn the APK
remote-control switch to the OFF position
and review the TROUBLESHOOTING guide
in the instructions supplied with the Peterson
remote control system.
6. To extinguish the log set, switch the APK
remote-control switch to the OFF position.
The log set should extinguish, but the pilot
will remain lit.
GAS LOG SET OPERATING INSTRUCTIONS (Cont.)
MAINTENANCE AND SERVICE
APK-11(M)
(Shown)
Note:
Heatshield is
not shown, but
must be in place
when operating
the gas log set.
Fig. 14-1