Owner`s manual
2
REV 4 - 0907131103
No. L-A2-01309
TABLE OF CONTENTS
IMPORTANT - Read This Manual Carefully Before Starting Installation of the Log Set
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any other
appliance.
Charred Series
Charred Oak (CHD)
Charred Split (CHS)
Charred Royal (CHB)
Some Available Log Styles:
Designer Series
Golden Oak Designer Plus
(RDP)
Split Oak (S)
Split Oak Designer Plus
(SDP)
Woodland Oak (WO)
Designer (EXD)
Royal English Oak
Designer (BD)
Heritage Designer (HD)
White Birch (W)
Golden Oak Designer (RD6)
Classic Series
Golden Oak (R)
Post Oak (PO)
Emberwood (E)
Royal English Oak (B)
Mountain Oak (K)
Twisted Pine (C)
PARTS LIST 3
FIREPLACE REQUIREMENTS 4
INSTALLING THE BURNER SYSTEM 5
INSTALLING THE DAMPER CLAMP 5
INSTALLING THE BURNER SYSTEM (Cont.) 6
PLACEMENT OF GRATE AND BURNER 6
CONNECTING THE GAS SUPPLY 6
INSTALLING THE BURNER SYSTEM (Cont.) 7
INSTALLING THE BURNER SYSTEM (Cont.) 8
INSTALLING THE BURNER SYSTEM (Cont.) 9
PLACEMENT OF GRANULES, GLOWING EMBERS AND GRATE 10
GRANULE PLACEMENT 10
GLOWING EMBERS PLACEMENT 10
GRATE REPLACEMENT 10
GAS LOG PLACEMENT 11
DESIGNER AND CLASSIC SERIES LOG PLACEMENT 11
CHARRED SERIES SUPPLEMENTAL INSTRUCTIONS 12
EMBER COALS PLACEMENT 12
CHARRED SERIES LOG PLACEMENT 12
GAS LOG SET OPERATING INSTRUCTIONS 13
LIGHTING INSTRUCTIONS 13
GAS LOG SET OPERATING INSTRUCTIONS (Cont.) 14
MAINTENANCE AND SERVICE 14
MAINTENANCE 14
SERVICE 14
FLAME DESCRIPTION 14
TROUBLESHOOTING THE GAS LOG SET 15
TROUBLESHOOTING THE GAS LOG SET (Cont.) 16
OPTIONAL CONTROLS FOR YOUR REAL-FYRE
®
BURNER SYSTEM 17
WARRANTY 18
When the log set is burning, the fi replace
damper must be fully open. The Peterson Real-
Fyre
®
gas log set is to be burned only in a fully
vented, noncombustible fi replace with damper and
chimney free of any obstructions. The fi replace
must be designed and approved to burn wood. As
with burning natural fi rewood, the Real-Fyre
®
log
set is designed to burn with yellow, smoky fl ames.
For this reason, it must be adequately vented. The
smallest dimension of the chimney fl ue must be at
least 8". If it is smaller, do not use this Real-Fyre
®
log set. If fumes from the burner emerge into the
room when the damper is fully open, creating a
smell like a smoldering oil lamp, it indicates that
the fi replace draft is defective. Check chimney fl ue
for obstructions. Do not operate the log set until
the fi replace draft is corrected. Check with the
dealer or installer. Do not use fi rewood with the
gas log set.