Owner`s manual
5
REV 4 - 0907131103
No. L-A2-01309
INSTALLING THE DAMPER CLAMP
Fig. 5-1
Damper clamp
INSTALLING THE BURNER SYSTEM
A damper clamp (Item #8) is provided as a means
to prevent full and/or accidental closure of the
fi replace damper when installed as illustrated
(Fig. 5-1). When the gas log set is operating,
the damper must be fully open. To install the
damper clamp:
1. Open the fi replace damper.
2. Place the damper clamp over the damper blade
(Fig. 5-1).
3. Tighten the set screw of the damper clamp
with pliers or a wrench so that it affi xes to the
damper blade. The clamp must be permanently
installed.
4. Should the damper clamp not fi t, install a
permanent damper stop or provide some other
means of preventing full and/or accidental
closure of the damper.
Open
Closed
Refer to the PARTS LIST section when installing the Real-Fyre
®
gas log set.
1. Carefully unpack the burner system. Check the PARTS LIST to be sure all parts are included.
2. The Real-Fyre
®
gas log set may be operated using a number of optional Peterson control
systems (see below), or with the remote gas valve of the fi replace. Peterson control systems
are engineered to provide convenient, safe, and reliable operation of the gas log set.
For safe operation, proper performance, and to comply with safety standards and certifi cations,
use only Robert H. Peterson Company control systems, parts, and accessories with the Real-
Fyre
®
gas log set.
Unpack the Peterson control system (if purchased) and check PARTS LIST provided with the control
to be sure all parts are included.