Owner`s manual

7
REV 4 - 0907131103
No. L-A2-01309
Check to see if the burner fuel injector or air mixer
is installed on the side of the burner closest to the
gas connection. The fuel injector or air mixer may be
mounted at either end of the burner pan. Be sure the
opposite end is capped tightly.
The Real-Fyre
®
gas log set can be installed using a
number of valve options. Proceed to the appropriate
section identifi ed with the valve option you are
using:
* Fireplace valve - Section 13A
* Peterson manual ON/OFF valve (AV series) -
section 13B
* Peterson manual safety pilot system (SPK
series) - section 13C
* Peterson remote safety pilot system (APK
series) - section 13D
a. Attach the hearth elbow (Item #9a) to the gas
supply stub in the fi replace. Use Tefl on tape or
pipe compound on the stub. Tighten securely.
b. Attach the smaller connector elbow (Item #9c)
to the fuel injector or air mixer on the burner
pan. Use Tefl on tape or pipe compound. Tighten
securely.
c. Connect the hearth elbow to the connector elbow
with the aluminum tubing (Item #9b). Tighten
both ends securely.
d. Use a long-necked butane lighter, or lay a lighted
match next to the burner pipe, and carefully turn
on the gas supply until the burner ignites.
e. Test for leaks at all connections with a soapy water
solution. If bubbles appear, a leak is present. Turn
off the gas and tighten all connections, turn on
the gas and repeat the leak test. Repeat until no
leaks are detected. Never use a fl ame to check
for leaks.
f. Turn off the gas supply.
g. Proceed to the GRANULE PLACEMENT
section.
INSTALLING THE BURNER SYSTEM (Cont.)
The AV Series is an ON/OFF control system for use
in a fi replace not supplied with its own valve. The solid
brass valve is CSA certifi ed. The AV-17 has a knob
handle and extension; the AV-18 has a steel rod handle.
This system requires a match or long-necked butane
lighter to manually ignite the log set.
a. Attach the hearth elbow (Item #9a) to the gas-
supply stub in the fi replace. Use Tefl on tape or
pipe compound on the stub. Tighten securely.
b. Attach the AV valve to the fuel injector or air
mixer on the burner pan using the
3
/
8
" elbow
supplied with the AV valve. Use Tefl on tape or
pipe compound. Tighten securely.
c. Discard the connector elbow (Item #9c) of
the connector kit. Be sure the fl ared adapter
supplied with the AV valve is securely attached
to the inlet side of the valve. Connect the hearth
elbow to the fl ared adapter with the aluminum
tubing (Item #9b). Tighten both ends securely.
d. Turn off the AV valve and turn on the gas
supply to the fi replace.
e. Use a long-necked butane lighter, or lay a lighted
match next to the burner pipe, and carefully turn
on the AV valve until the burner ignites.
f. Test for leaks at all connections with a soapy water
solution. If bubbles appear, a leak is present. Turn
off the gas and tighten all connections, turn on
the gas and repeat the leak test. Repeat until no
leaks are detected. Never use a fl ame to check
for leaks.
g. Turn off the AV valve.
h. Proceed to the GRANULE PLACEMENT
section.
Installing the Real-Fyre
®
gas log set using a
Peterson manual ON/OFF system (AV series)
(Fig. 7-2).
13B.
Installing the Real-Fyre
®
gas log set using the
valve supplied with fi replace (Fig. 7-1)
13A.
Fig. 7-1 Fireplace valve
Connector elbow
Gas-supply line
Air mixer/fuel injector
Burner pan
Hearth
elbow
Aluminum
tubing
Fig. 7-2 - AV series
Gas-supply
line
Hearth elbow
Aluminum
tubing
AV-17 or AV-18
valve
Flared adapter
Burner pan
Air mixer/fuel injector