Owner`s manual

8
REV 4 - 0907131103
No. L-A2-01309
INSTALLING THE BURNER SYSTEM (Cont.)
Fig. 8-1 - SPK-20 system
13C. Installing the Real-Fyre
®
gas log set using a Peterson manual safety pilot system (SPK series)
(Fig. 8-1 & Fig. 8-2)
The Peterson SPK Control Systems make enjoying the Real-Fyre
®
gas log set convenient and trouble-free.
Just a turn of the knob (SPK-20, SPK-26, SPK-32, or SPK-33) or steel rod handle (SPK-21) allows you to
easily ignite or extinguish the log set. The SPK Series is available for natural or propane gas and will continue
to operate during power failures, as it requires no outside source of electricity to operate.
The valve is CSA certifi ed, and the standing pilot is adjustable. The built-in safety feature automatically shuts
off the gas fl ow should the pilot go out. A convenient pressure tap is included for easy gas pressure testing.
Advanced heat shielding adds greater heat protection for cooler, long-lasting operation.
a. Carefully follow the instructions supplied with the Peterson manual safety pilot kit for steps to
assemble the safety pilot system and install it on the burner pan.
b. Carefully turn on the gas supply, ignite the burner pan, and test for leaks at all connections with a soapy
water solution. If bubbles appear, a leak is present. Turn off the gas and tighten all connections, turn on
the gas and repeat the leak test. Repeat until no leaks are detected. Never use a fl ame to check for
leaks.
c. Turn off the SPK system.
d. Proceed to the GRANULE PLACEMENT section.
Note: Heatshield is
not shown,
but must be
in place when
operating the
gas log set.
FRONT FLAME BOOSTER
FUEL INJECTOR
BURNER
PA N
SPK VALVE
CONNECTOR
TUBE
ELBOW
GAS SUPPLY
LINE
FRONT FLAME BOOSTER
FUEL INJECTOR
BURNER
PA N
SPK VALVE
CONNECTOR
TUBE
ELBOW
GAS SUPPLY
LINE
Fig. 8-2 - SPK-26 system
Front fl ame
booster
SPK
valve
Burner pan
Fuel injector
Connector
tube
Elbow
Gas-supply
line
SPK valve
Brass
adapter
Pressure
tap
SPK valve
SPK valve
Gas-supply
line
Elbow
Connector
tube
Burner pan
Fuel injector