Owner`s manual
3
L-A2-007
REV 1-1005110932
Orifice
Pilot Gas
Supply Line
BRASS
ADAPTER
FUEL
INJECTOR/
AIR MIXER
SV-12
VALVE
OUTLET
PORT
FLAME DIVERTER
BRACKET
THERMOCOUPLE
PILOT GAS
SUPPLY LINE
PILOT
ASSEMBLY
Fig. 3-1
This safety pilot kit must be installed by a qualifi ed professional. Instructions must be followed carefully
when installing to ensure proper performance and full benefi t from the gas log set and safety pilot kit.
These instructions must be used as a supplement to the instructions supplied with the Peterson gas log set.
Follow the gas log set instructions and make adjustments as appropriate for the addition of a safety pilot kit. Use
gas pipe sealing compound that is resistant to all gases, or Tefl on tape, and apply to all male pipe connections.
Make sure that all connections are tight and do not leak.
FOR PROPANE GAS
The safety pilot kit is shipped with a natural gas orifi ce
installed unless the safety pilot kit was received in
the same box as the propane burner. To change from
natural to propane gas, remove the pilot gas supply line
at the pilot end. Replace the natural gas orifi ce with the
propane gas orifi ce contained in the yellow envelope
marked "L.P.-GAS", provided in the bag. Reattach the
pilot gas supply line to pilot (Fig. 3-1).
STEP 1: CONNECTING THE SAFETY VALVE TO
THE BURNER
A. Remove the heatshield, extension handle, and
knob, if required.
B. Screw the brass adapter to the fuel injector or air
mixer on the burner (Fig. 3-1).
FOR LEFT-SIDED INSTALLATION:
A. Make sure the fuel injector/air mixer and burner
cap are reversed so the the fuel injector is on the
left side of the burner and the cap is on the right.
B. Turn the brass adapter 180 degrees on the safety
valve so the opening is to the right and then mirror
illustrations for left-sided installation.
C. Reconfi gure heatshield to protect the valve body.
STEP 2: INSTALLING THE FLAME DIVERTER
BRACKET
Purpose
The fl ame diverter bracket, when properly installed
onto Peterson G4, GX4, VG4, and P series burner pans
equipped with a safety control system, will promote
quicker ignition of the Peterson gas log set and protect
the safety control system from overheating.
A. Install the flame diverter bracket before
installing the pilot assembly.
B. Place fl ame diverter bracket over the side edge of
the burner pan where the Peterson safety control
system pilot bracket will be attached. Bracket should
be placed approximately 1
1
/
4
" from the back of burner
pan (Fig. 3-2, 3-3, & 3-4).
C. Tap bracket lightly with hammer to secure in
place.
CAUTION: Be careful not to kink the pilot gas
supply tube or thermocouple.
Example of left-sided installation
Fig. 3-2
Fig. 3-4
Fig. 3-3
Heatshield is
not shown, but
must be in place
when operating
the log set.
Note:
Pilot gas
supply line
Pilot
assembly
SV-12
valve
Outlet
port
Brass
adaptor
Fuel
injector/
air mixer
Flame divertor
bracket
Thermocouple
Pilot gas
supply line
Pilot
assembly
1 1/4"
Burner
pipe
Flame diverter
bracket
Burner pipe
Pilot
assembly
Burner pipe
Burner pan
Pilot
assembly
Pilot bracket
Insulation
pad
Attach
1 1/4"
Orifi ce
HOW TO ASSEMBLE THE SAFETY PILOT KIT
Flame
diverter
bracket
Flame diverter
bracket