Owner`s manual

4
L-A2-20707
REV 5 - 0705071310
MODEL
NO.
LOG SET DIMENSIONS BTUs
FRONT BACK DEPTH NATURAL PROPANE
G45-18/20 20" 15" 12" 75M 50M
G45-24 24" 20" 12" 90M 65M
G45-30 30" 24" 12" 90M 65M
Note: It is recommended that complete fi rebox dimensions (front width, back wall, and
height) be obtained to ensure proper sizing.
IMPORTANT INFORMATION
Important - Read this manual carefully before starting installation of the log set.
Check to be sure the fi replace meets venting and construction requirements for the installation of
the Real-Fyre
®
gas log set (see FIREPLACE REQUIREMENTS section, below).
Be sure your gas log set is properly sized for your fi replace. Improper sizing may negatively impact the
proper drafting of the fi replace. Additionally, too large a log set will adversely affect the burn and hamper the
proper operation of the control system. Too small a log set will diminish the beauty of your hearth setting.
Fig. 4-1 below shows the critical dimensions of your fi rebox. The table below shows log set
dimensions.
PRE-INSTALLATION REQUIREMENTS
Check that the gas log set is correct for the type of gas that is used in the fi replace.
If not, DO NOT INSTALL. Contact the Real-Fyre
®
dealer for advice.
Never use propane gas in a log set manufactured for natural gas.
This Real-Fyre
®
gas log set is to be installed only in
a fully vented, noncombustible fi replace with an open
damper. The chimney must be free of any obstructions.
The fi replace must be designed and approved to burn
wood. Your Real-Fyre
®
log set is designed to burn
with yellow, smoky fl ames. For this reason, it must
be adequately vented. The fi replace fl ue must be at
least 8" at its smallest dimension. If it is smaller,
do not use this Real-Fyre
®
log set.
The fi replace must have a gas-supply line that has
been installed by a qualifi ed technician in accordance
with all local codes. The gas-supply line must be
½" minimum interior diameter. If the gas line to the
replace is longer than 20', a larger-diameter line may
be necessary.
Required Gas Pressure: The minimum inlet gas-
supply pressure for the purpose of input adjustment
is 7" of water column (w.c.) for natural gas and 11"
w.c. for propane.
The maximum inlet gas-supply pressure is 10.5" w.c.
for natural gas and 13" for propane.
FIREPLACE REQUIREMENTS
Fireplace Dimensions
Height
Depth
Front
width opening
Fig. 4-1
PRIOR TO INSTALLING THE LOG SET, the gas-
supply line must be tested. Follow the guide lines
set by NFPA 54 or local code requirements.
A. Ensure the gas supply to the fi replace is turned off.
B. Clean the fl oor of the fi replace of any dirt or ashes.
C. Chimney must be cleaned and inspected.
Important: To comply with certifi cation, listings, and building code acceptances, and for safe
operation and proper performance of this log set, use ONLY Peterson Real-Fyre
®
parts
and accessories. Use of other controls, parts, and accessories that are not designed for
use with Real-Fyre
®
gas log sets is prohibited and will void all warranties, certifi cations,
listings, and building code approvals, and may cause property damage, personal injury,
or loss of life.
Rear
width