Owner`s manual

11
LIGHTING THE GAS LOG SET
1. After you have fi nished checking for leaks, ensure that the unit is turned completely off by pushing in the
ON/OFF control knob and turning clockwise toward OFF until you reach a stop.
2. Turn the ON/OFF control knob counter-clockwise to the ON position. DO NOT PUSH KNOB IN!
Note: You should not hear or smell any gas at this point.
3. Wait fi ve (5) minutes to clear out any gas. Smell for gas, including near the fl oor. If you smell gas, stop
and follow step B of the safety information above. If you don’t smell gas, go to the next step.
4. LIGHTING INSTRUCTIONS
a. Press and hold in the electronic ignitor button. The ignitor will spark with a rapid clicking noise.
b. While holding in the electronic ignitor, push in the ON/OFF control knob to open the valve. Burner will
now ignite at the maximum BTU input.
c. Continue to hold knob for 10-15 seconds; this will allow the safety valve to activate and the main burner
to remain burning.
Note: Electronic igniter may not properly operate when exposed to high moisture. To manually light the
burner, lay a long-stem match on the surface of the embers near the gas inlet (do not hold the
match in your hand) or use a lighted long necked butane lighter.
TURNING OFF THE GAS LOG SET
1. Push in the ON/OFF control knob and turn clockwise
toward OFF until you reach a stop (burner will
extinguish).
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result, causing property
damage, personal injury, or loss of life.
A. BEFORE LIGHTING, smell all around the gas
log set area for gas. Be sure to smell next to the
oor because some gas is heavier than air and
will settle on the fl oor.
B. IF YOU SMELL GAS:
Shut off the gas to the appliance.
Extinguish any open fl ame.
If odor continues, keep away from the
appliance, and immediately call the gas
supplier or fi re department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, don’t try to repair it. Call
a qualifi ed service technician. Force or attempted
repair may result in fi re or explosion.
D. Do not use the gas log set if any part has been
underwater. Immediately call a qualifi ed service
technician to inspect the gas log set and to replace
any part of the control system and any gas control
that has been underwater.
Electronic ignitor
On/Off
control
knob
Fig. 11-1
OPERATING THE LOG SET - LIGHTING AND EXTINGUISHING
REV 0 - 1407291335
L-A2-293