Owner`s manual

3
The installation, including provisions for combustion
and ventilation air, must conform with local codes or,
in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 (latest edition).
This appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
when testing at pressures exceeding
1
/
2
psig. Do this
by closing the gas supply valve.
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any testing of the gas supply system at
test pressures up to and including
1
/
2
psig.
WHEN GLASS FIREPLACE ENCLOSURES
(DOORS) ARE USED, OPERATE THE GAS LOG
SET WITH THE GLASS DOORS FULLY OPEN;
BOTH SIDES IF FIREPLACE IS SEE-THRU TYPE.
IMPORTANT INFORMATION
Item Description
1. Radiant heatshield
2. Valve assembly
Safety valve
Brass elbow (fl are)
3
/
8
" NPT close nipple
3
/
8
" coupling
Street elbow 3/8 (3 req.)
Toggle switch
Switch bracket
3. Flame diverter bracket
4.
Fuel injector (for use with
natural gas log sets only)
Air mixer not shown (for use
with propane gas log sets)
Item 4 is supplied with burner assembly
Item Description
5. Pilot assembly
Generator
Pilot gas supply
6. Screw #10 x 3/8 PH, BLK
(4 req.)
7. Mounting bracket
8. Burner insulation pad
9. Connector kit
(supplied w/burner)
10.
1
/
4
" slotted bolt and nut
(For front fl ame burner installation only.
Not shown in illustration above.)
11. Fuel injector (enlarged for use
with 24" - 30" natural gas log sets)
12. RR-1A remote kit (if equipped)
PARTS LIST
Remote kit with remote
instructions.
12
(If equipped)
6
2
5
8
7
1
6
3
4
CK-4 CONNECTOR KIT
SUPPLIED WITH BURNER
SMALL BRASS
CONNECTOR
(DO NOT USE)
HEARTH
ELBOW
CK-4 CONNECTOR TUBE
9
6
2
5
8
7
1
6
3
4
CK-4 CONNECTOR KIT
SUPPLIED WITH BURNER
SMALL BRASS
CONNECTOR
(DO NOT USE)
HEARTH
ELBOW
CK-4 CONNECTOR TUBE
9
11
(14 D.S.)
11
(14 D.S.)
CK-4 Connector tube
Hearth
elbow
Brass
elbow
Street
elbow
Pilot gas
supply
Generator
spade clips
Small brass connector
(do not use)