4.3  Mounting and installation 
4.3.1  Dimensions 
The main dimensions of the two models of the product are described in the following illustrations. 
003 dimensions (mm) 
H1  H2  H3  W1  W2  W3  D1  D2 
157  147  137  66  38  4.5  99  7 
006 dimensions (mm) 
H1  H2  H3  W1  W2  W3  D1  D2 
195  183  170  122  102  6  122  20 
4.3.2  Mounting 
There are two possible ways to mount a frequency converter to the panel: screw or DIN rail mounting (model 003 
only). The measurements for  placing  the  holes  and  the  screw size  to  be  used  are  marked  on the  back  of  the 
frequency converter. 
The frequency converter has forced airflow cooling so the device can be mounted at any angle without affecting its 
operation. 
Screw mounting without integrated braking resistor 
1 
Initially tighten the screws so that they can be fitted in the holes in 
the upper part of the frequency converter. 
Model 003 screw size: M4 
Model 006 screw size: M5 
Model 012 screw size: M5 
Use screw locking liquid. 
2 
Once the device is held up by the screws, tighten the upper screws 
and then secure the lower part with a screw. 