5.2  Switch settings in traveling movement application 
Converter’s default application is traveling movement application. Application can be changed with switch group 
S10-2. 
Switch S10- 2  Chain hoist lifting application 
0  The chain hoist lifting application is not active. 
1  The chain hoist lifting application is active. 
In traveling movement application ie.  when chain hoist lifting application is not active the switches must be set 
according to the descriptions in the following sections. 
5.2.1  S9 Motor nominal frequency in traveling movement application 
The motor’s nominal frequency and voltage are selected according to the values presented in the following table. If 
the  first  alternative is  selected  and  the  mains  voltage  is 400  V,  the  maximum  frequency  (switch  S1)  must  not 
exceed 100 Hz. 
Switch S9 
Motor nominal frequency  Motor nominal voltage 
- 1  - 2 
0  0  100Hz / 120Hz  400 V / 460 V 
0  1  80Hz  400 V 
1  0  35Hz  400 V 
1  1  Parameter fault  Parameter fault 