Service Manual
R&M Materials Handling, Inc. 
4501 Gateway Boulevard 
Springfield, Ohio 45502 
P.: (937) 328-5100 
FAX: (937) 325
-
5319
23/53 
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
5.2.2  S1 Maximum driving frequency in traveling movement application 
This  switch  group  adjusts  the  maximum  driving  frequency  of  the  motor.  The  switch  settings  are  shown  in  the 
following table. The selected motor nominal frequency (switch group S9) defines which column of the table is used. 
The maximum driving frequency shall not be set higher than the nominal frequency of the motor. 
Note: The 100 Hz nominal frequency may be exceeded only if the line voltage is at least 460V. 
Switch S1  Maximum driving frequency 
-1  -2  -3 
Maximum frequency for 
100/120 Hz motor 
Maximum frequency for 
80 Hz motor 
Maximum frequency for 
35 Hz motor 
1  1  1  50  55  26 
1  1  0  60  60  28 
1  0  1  70  65  30 
1  0  0  85  70  33 
0  1  0  95  75  35 
0  0  0  100  80  19 
0  1  1  110(*)  45  21 
0  0  1  120(*)  50  24 
(*) May only be used if the line voltage is at least 460V. 