Service Manual
R&M Materials Handling, Inc. 
4501 Gateway Boulevard 
Springfield, Ohio 45502 
P.: (937) 328-5100 
FAX: (937) 325
-
5319
24/53 
R&M Materials Handling, I
nc. reserves the right to alter or amend the above information without notice.
5.2.3  S2 Minimum driving frequency in traveling movement application 
This  switch  group  adjusts  the  minimum  driving  frequency  of  the  motor.  The  switch  settings  are  shown  in  the 
following table. The selected motor nominal frequency defines which part of the table is used. 
Switch S2  Minimum driving frequency 
-1  -2  -3 
Minimum frequency for 
100/120 Hz motor 
Minimum frequency for  
80 Hz motor 
Minimum frequency for  
35 Hz motor 
0  1  1  12  24  4 
0  0  0  14  10  5 
0  0  1  16  12  6 
1  0  1  20  14  7 
1  0  0  23  20  8 
0  1  0  26  18  9 
1  1  0  28  16  10 
1  1  1  30  22  3 