5.2.6  S8 Number of motors in traveling movement application 
The model is only used with compact brake motors, which need DC (direct current) to open the brake at the start 
and to keep the brake open during electrical braking. Depending on the nominal current of the frequency converter, 
up to four motors can be connected to it. Thus start and stop DC must be adjusted to the right level with switch 
group S8. 
Switch S8  Number of Motors 
-1  - 2  - 3  Number of Motors 
003 
Current [A
rms
] 
006 
Current [A
rms
] 
0  0  0  1  3  3 
0  0  1  2  4.8  6 
0  1  0  3  -  9 
0  1  1  4  -  12 
Note: Other settings will cause parameter fault. 