2  PARAMETER ADJUSTMENTS 
2.1  The display panel 
READY FAULT
STOP
RUN ALARM
V 4.18.
Motor Speed
 2002 rpm
START
STOP
enter
selec
t
reset
ready
run
fault
I/O term Keypad
The display panel is used for: 
Displaying the drive identification, electrical values, operating or fault parameters 
Altering the parameter settings 
Saving and restoring the parameter settings in the memory of the display panel 
Meaning of the displays: 
RUN
Motor is running, blinks when ramping down. 
Direction of motor rotation. 
STOP
Motor is not running. 
READY
Power is on. In case of a trip, the symbol will not light up. 
ALARM
Drive is running outside of certain limit. 
FAULT
Fault is on 
I/O term
I/O-terminals are the selected control place 
Keypad
Keypad is the selected control place 
The signalling LED’s 
“ready”  Power is on. 
“run”  Motor is running, blinks when ramping down. 
“fault”  Fault trip 
Button description 
reset
Reset active faults 
select
Switch between two latest displays 
enter
Confirmation of selections 
Fault history reset 
Browse the main menu and the pages of submenus 
Edit values 
Move in menu 
Move cursor 
Enter and exit edit mode 
START
Start button 
Starts motor if the keypad is the active control place 