Property R-Tech Test Method
Nominal Density (pcf) 1.0 ASTM C303
C-value (Conductance)
BTU/(hr-ft2-°F)
@ 25° F
(per inch) @ 40° F
@ 75° F
.23
.24
.26
ASTM C518
or
ASTM C177
R-value
(Thermal Resistance)
(hr-ft2-°F)/BTU
@ 25° F
(per inch) @ 40° F
@ 75° F
4.35
4.17
3.85
ASTM C518
or
ASTM C177
Compressive Strength
(psi, 10% deformation)
10 ASTM D1621
Flexural Strength (psi) 33 ASTM C203
Dimensional Stability
(maximum %)
2% ASTM D2126
Water Vapor Transmission
(perms)
< 1.0 ASTM E96
Absorption (% vol.) < 1.0 ASTM C272
Capillarity None
Flame Spread 20 ASTM E84
Smoke Developed 150 - 300 ASTM E84
R-Tech
Thickness
Design
Temp.
Effective
R-value
(R-Tech MR
+ Air Space)
b
0.5"
40° F
75° F
4.90
4.80
1.00"
40° F
75° F
7.00
6.70
1.50"
40° F
75° F
9.10
8.60
2.00"
40° F
75° F
11.10
10.50
3.00"
40° F
75° F
15.40
14.50
Typical Physical Properties of R-Tech* Effective R-value
a
(metallic-reflective facer and dead air space)
*Properties are based on data provided by resin manufacturers,
independent test agencies and Henry.
a Effective R-value determined using R-Tech 1.0. Higher
density R-Tech products will provide higher R-value gains.
The type of construction application and the depth of the
air space will also impact the actual Effective R-value.
b Requires 0.75”- 3.50” dead air space and the R-Tech
MR facer towards the dead air space.
Sizes
R-Tech is available in 4’ x 8’ sheets with thicknesses of: 1/2”, 1”, 1-1/2”, 2” and 3”.
For more information, visit www.henry.com or for technical assistance call us at 800-486-1278. Refer to the Safety Data Sheet prior to using this product. The Safety Data Sheet is available at www.henry.
com or by emailing Henry Product Support at productsupport@henry.com or by calling 800-486-1278.
Henry, R-Tech and #1 Choice of Professionals are registered trademarks of Henry Company
The technical and application information herein is based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made
as to a product’s suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is
responsible for checking the suitability of products for their intended use. Henry Company data sheets are updated on a regular basis; it is the user’s responsibility to obtain and to confirm the most recent
version. Information contained in this data sheet may change without notice.