Specification

Typical Physical Properties of R-Tech
Property Type I Test Method
Nominal Density (pcf) 1.0 ASTM C303
C-Value (Conductance)
BTU/(hr•ft
2
•°F)
@ 25° F
(per inch) @ 40° F
@ 75° F
.23
.24
.26
ASTM C518
or
ASTM C177
R-Value
(Thermal Resistance)
(hr•ft
2
•°F)/BTU
@ 25° F
(per inch) @ 40° F
@ 75° F
4.35
4.17
3.85
ASTM C518
or
ASTM C177
Compressive Strength
(psi, 10% deformation)
13 ASTM D1621
Flexural Strength (psi)
33 ASTM C203
Dimensional Stability
(maximum %)
< 2% ASTM D2126
Water Vapor Transmission
(perms)
< 1.0 ASTM E96
Absorption (% vol.)
< 1.0 ASTM C272
Capillarity none
Flame Spread < 20 ASTM E84
Smoke Developed 150 - 300 ASTM E84
*Properties are based on data provided by resin manufacturers, independent test
agencies and Insulfoam.
6012 - 03/10
R-Tech
Thickness
Design Temp.
Effective R-Value
(R-Tech MR + Air Space)
b
0.50"
25º
40º
75º
5.00
4.90
4.80
0.75"
25º
40º
75º
6.10
5.90
5.70
1.00"
25º
40º
75º
7.20
7.00
6.70
1.25"
25º
40º
75º
8.30
8.00
7.60
1.50"
25º
40º
75º
9.40
9.10
8.60
1.75"
25º
40º
75º
10.50
10.10
9.60
2.00"
25º
40º
75º
11.60
11.10
10.50
2.25"
25º
40º
75º
12.70
12.20
11.50
2.50"
25º
40º
75º
13.80
13.20
12.40
Effective R-Values
a
(metallic-reective facer and dead air space)
a Effective R-Values determined using InsulFoam I. Higher density InsulFoam
products will provide higher R-Values. The type of construction application and
the depth of the air space will also impact the actual Effective R-Value.
b Requires 0.75"- 3.50" dead air space and the R-Tech MR facer towards the dead
air space.
6012_RT_Insulation.indd 2 3/29/10 5:23:41 PM