TECHNICAL DATA
Voltage 230 V, 1 50/60 Hz
Permissible load at
100% duty cycle 100 A / 19 V
60 % duty cycle 120 A / 20 V
35 % duty cycle 150 A / 21.5 V
Setting range (DC) 30A / 15.5 V--160A / 22 V
Open circuit voltage 60 V
Open circuit power 15 W
Efficiency 82%
Power factor 0.99
Wire feed speed 2 -- 11m/min
Wire diameter
Fe
CW
0.8 (0.6--1.0)
0.8--1.0
Bobbin size 200 mm
Dimensions lxwxh 449x198x347
Weight 12 kg
Operating temperature --10 to +40
o
C
Enclosure class IP 23C
Application classification
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23C is designed for indoor and outdoor use.
Application class
The symbol indicates that the power source is designed for use in areas with increased
electrical hazard.