Specifications

Connections for using gas/gasless wire
1. Gas type wire
Connect as per diagram above, A is power outlet, B is + to torch
Fit earth lead to - negative connector on front of machine
2. Gasless type wire (reverse polarity required for gasless wire)
Connect brass bar from A to C so torch is negative
Fit earth lead to + positive connector on front of machine
Note:
Ensure machine is disconnected from mains before changing torch polarity.
- 16 -