5.5.3. Alarm Control
Alarm response time may be set between 1 and 5 minutes.
Alam Mask allows the user to customize the type of alarms sent to the SNMP server when
remote monitoring is in use.
5.5.4. Band select
Band select sets the digital filter to the center frequency and bandwidth of the local service
for which the repeater is intended to ampligy. Likewise, all other signals outside of the selected
Center Frequency and Bandwidth are rejected.
The user can select one, two three distinct sections within the PCS band. Each of the 1st, 2nd
and 3rd filter blocks can be set to 1MHz to 20MHz of Bandwidth. Only the downlink center
frequency is set by the user. The uplink center frequency are automatically set in acordance
with the downlink frequencies.
Filter Rejection allows the user to change the digital filter characteristics. Normal rejectrion is
used for CDMA and EVDO service. High regection is used for LTE service.
Frequency information is available as a reference for seting the center frequency and band
width (refer to section 7).
5.6. GUI System Control
5.6.1. Manual Setting [Recommended]
5.6.1.1. Auto Gain Control Setting
Step 1. Isolation Check
The Isolation will calculate the Available Maximum Gain which defines the maximum gain to
be setup.
Click Isolation