User's Manual
14 / 54
User Manual
Rev. 2.1 - 26/06/19
TEX1002LCD
L 
N 
PE 
If transmitter require three-phase power with 3F (black, brown and grey) + N3F (black, brown and grey) + N 
(blue) + GND (green yellow), keep in mind this requirement to connect to your, keep in mind this requirement to connect to your 
distribution board.
R 
S 
T 
N 
PE 
 Note: the mains must be equipped with adequate earth connection  properly 
connected to the equipment. This is a pre-requisite for ensuring operator safety 
and correct operation.
The following table shows the recommended cable cross-sections:
CONNECTOR
THREE-PHASE
CABLE SECTION
SINGLE-PHASE 
CABLE SECTION
L
/ Ø 2,5mm
R
Ø 1,5mm /
S
Ø 1,5mm /
T
Ø 1,5mm /
N
Ø 2,5mm Ø 2,5mm
PE
Ø 2,5mm Ø 2,5mm
Tipically the distribution board contains the thermal-magnetic circuit breakers for 
each amplifier included in the system and one for service.










