User's Manual

TEX100LCD/S
ELETTRONICA
13 / 36
User Manual
Rev. 2.0 - 26/06/19
L
N
PE
If transmitter require three-phase power with 3F (black, brown and grey) + N3F (black, brown and grey) + N
(blue) + GND (green yellow), keep in mind this requirement to connect to your, keep in mind this requirement to connect to your
distribution board.
R
S
T
N
PE
Note: the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.
The following table shows the recommended cable cross-sections:
CONNECTOR
THREE-PHASE
CABLE SECTION
SINGLE-PHASE
CABLE SECTION
L
/ Ø 6mm
R
Ø 4mm /
S
Ø 4mm /
T
Ø 4mm /
N
Ø 4mm Ø 6mm
PE
Ø 4mm Ø 6mm
Tipically the distribution board contains the thermal-magnetic circuit breakers for
each amplifier included in the system and one for service.