WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the distribution board of the transmitter is set to “OFF”.
5.1.3 Device power supply connections
Provide for the following (applicable to operating tests and putting into service):
√ Single-phase 230 VAC or 115 VAC (-15% / +10%) mains power supply for
TEX100LCD/S, both with adequate earth connection.
√ For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (100W as a minimum for TEX100LCD/S).
Note: to ensure the safety of the operators, carry out the wiring according to the
laws and regulations in force in the country where this equipment is installed.
Check that the POWER switch on the front of TEX100LCD/S is in the OFF
position..
The transmitter has two switches: one is embedded in VDE socket for mains power
cord and interrupts all mains power supply of the machine, while the second is on
the front panel and acts by inhibiting the switching power supply of the machine.
Connect the mains power cable to the MAINS connector on the rear panel.
Warning: Be sure to connect the equipment correctly, to avoid the risk of
damaging. It is necessary connect the ground conductor of the power supply
cable to the specific terminal in the multipole socket and check the efficiency of
your own grounding system.
The control and RF connection diagram, between the amplifier and its exciter,
and the connection with the load are represented in figure 5.1.