User's Manual

TEX100LCD/S
ELETTRONICA
Connector XLR F
Type Balanced
Impedance Ohm 10 k or 600 Selectable by rear panel dip switches
Input Level /Adjust dBu -13 to +13 continuosly variable
Connector XLR F
Type Balanced
Impedance Ohm 10 k or 600 Selectable by rear panel dip switches
Input Level dBu -13 to +13 continuosly variable
Connector BNC
Type unbalanced
Impedance Ohm 10 k or 50 Selectable by rear panel dip switches
Input Level / Adjust dBu *-13 to +13 for 75 KHz FM, externally adjustable
Connector 2 x BNC
Type unbalanced
Impedance Ohm 10 k
Input Level / Adjust dBu *-8 to +13 for 7,5 KHz FM, externally adjustable
Connector XLR F
Type Balanced
Impedance Ohm 110
Input Level / Adjust dBfs 0 to -10 for 7,5 KHz FM, externally adjustable
Connector TOS-LINk
Type Optical
Connector N type
Impedance Ohm 50
Connector BNC
Impedance Ohm 50
Output Level dB approx. -60 Referred to the RF output
Connector BNC For RDS and isofrequency synchronizing purpose
Impedance Ohm >5 k
Output Level Vpp 1
Interlock Connector BNC Input and output for remote power inhibition (short is RF off)
Service Connector DB9 F Factory reserved for firmware program
Remote Interface Connector DB15F IIC + 5 analog / digital inputs, 5 analog / digital outputs
FUSES
On Mains 1 External fuse F 6,3 T - 5x20 mm
On services
On PA Supply
On Driver Supply
Input device 4 pushbutton
Display Alphanumerical LCD - 2 x 16
10 FWD fold For P.A. A.G.C. purpose, min 0,5 Vcc
2 REF fold For P.A. A.G.C. purpose, min 0,5 Vcc
14 RF ON
15 RF OFF
Close to GND 1 Interlock for remote power inhibition (short is RF off)
6 FWD max 5 Vcc
13 REF max 5 Vcc
5 VPA max 5 Vcc
12 IPA max 5 Vcc
Open Collector 7 Power Good open collector
Remote connector inputs
Analogical level
Pulse to GND
Remote connector outputs
Analogical level
RF Output
RF Monitor
Pilot output
AUXILIARY CONNECTIONS
HUMAN INTERFACES
TELEMETRY / TELECONTROL
Right
MPX
SCA/RDS
AES/EBU
(optional)
TOS/Link
(optional)
OUTPUTS
AUDIO INPUTS
Left / Mono