Connect the RF output of the transmitter to an antenna cable or to a dummy load
capable of dissipating the power generated by the amplifier. To begin with, set
transmitter to minimum output power and switch if off.
Connect the amplifier INTERLOCK OUT output to the matching INTERLOCK IN
input fitted on all R.V.R. Elettronica transmitters as standard; if your transmitter is
a different brand, identify an equivalent input.
Connect the RF output to an adequately rated dummy load or to the antenna.
WARNING: To avoid electrical shock and electrocution, never touch the RF
output connector when the equipment is switched on and no dummy load
is connected.
Ensure that the POWER switch on the front panel of TEX702LCD is set to
OFF”.
The transmitter has two switches: one is embedded in VDE socket for mains power
cord and interrupts all mains power supply of the machine, while the second is on
the front panel and acts by inhibiting the switching power supply of the machine.
Connect the mains power cable to the MAINS connector on the rear panel.
Note: the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.
Connect the audio and RDS/SCA signals from user’s sources to the transmitter
input connectors.
Note: RF EXPOSURE SAFETY DISTANCE (only for FCC & IC)
RF Exposure Limits for United States of America, according to FCC regulation:
setting to the maximum of the output power of the apparatus, to guarantee
the limits of exposure declared within this document, it is necessary that
the antenna gain used with this device should be 0dBi or less and all
persons should maintain a minimum separation distance of 528.50 cm for
general uncontrolled exposure and general controlled exposure.
RF Exposure Limits for Canada, according to IC regulation: setting to the
maximum of the output power of the apparatus, to guarantee the limits of
exposure declared within this document, it is necessary that the antenna
gain used with this device should be 0dBi or less and all persons should
maintain a minimum separation distance of 657.81 cm for general uncontrolled
exposure and general controlled exposure.
Limites d’exposition RF: en réglant au maximum de la puissance de sortie de
l’appareil, afin de garantir les limites d’exposition déclarées dans ce document, il
est nécessaire que le gain d’antenne utilisé avec cet appareil doit être de 0 dBi
ou moins et toutes les personnes doivent conserver une distance de séparation
minimale de 657.81 cm pour les expositions générales non contrôlées et les
expositions générales contrôlées.