User's Manual

TEX702LCD
ELETTRONICA
19 / 36
User Manual
Rev. 2.0 - 26/06/19
To set subcarrier input levels, you may use the same procedure and option “x10”
available in the Fnc menu. With this option, modulation level is multiplied by a factor
of 10, which means that default menu bar meter reflects a 7.5 kHz deviation.
A special menu with separate indications of Left and Right channel levels and
relating indicators of nominal levels for maximum deviation (75 kHz) is provided.
Preemphasis:
ON
1
2
3
4
50 ms
ON
1
2
3
4
75 ms
L and R (XLR type) input impedance:
Switch 1: R XLR input impedance, ON = 600 W, OFF = 10 kW
Switch 2: L XLR input impedance, ON = 600 W, OFF = 10 kW
MPX input operation mode/impedance:
Switch 1: Mode of operation ON = Mono, OFF = Stereo
Switch 2: MPX input impedance, ON = 50 W, OFF = 10 kW
5.2 Operation
1) Power on the transmitter and ensure that the ON light turns on. Equipment
name should appear briefly on the display, quickly followed by modulation and
forward power readings (Menu 1), provided that the transmitter is delivering
output power.
Menù 1
1b) In case of a password has been set, through the Miscellaneous menu, enterIn case of a password has been set, through the Miscellaneous menu, enter
the code and then confirm to be able to view or modify the parameters of the
machine.
ON
1 2
ON
1 2