Cut Sheet

FXH150PSQ
JOB NAME:
DATE:
TYPE:
DESCRIPTION
Medium base HPS, MH or CFL specification grade flood with Integra Hood glare shield.
Lamp supplied.
SPECIFICATIONS
Finish:
Chip and fade resistant polyester powder
coating
Ground Mounting:
Use the new MPM19 Mighty Post with
aluminum cap for sturdy installation
Housing:
Precision die cast aluminum. 1/2" NPS
locking Swivel Arm, Wall Bracket Trunnion
or Slip Fitter
Lens Frame & Glare Shield:
Precision die cast aluminum. Hinged for
easy access. Phillips head screws for added
security
Lens Gasket:
High temperature one piece molded silicone
set in die cast retaining groove. Remains in
place during relamping
Lens:
Thermal tempered shock resistant glass,
3/16" thick
Reflector:
Anodized aluminum. Field adjustable beam
spread. Rotates 90° for horizontal or vertical
lamp position
Socket:
HID: Porcelain 4kv Pulse Rated socket with
nickel plated screw shell CFL: Plug in
type, GX24q-4 base
UL Listing:
Suitable for wet locations. Suitable for
mounting within 4' of the ground
EPA:
Maximum EPA: 1.1
Patents:
Pat. D545,472
Pulse Start:
Pulse Start metal halide for increased lamp
life, lumen maintenance, color uniformity and
efficiency
Color:
Bronze
Weight:
15.55
DIMENSIONS
PHOTOMETRIC
ORDERING INFORMATION
Metal Halide
Total
Watts
Lamp
Type
Lamp
Base Ballast
Starting Amps/ Operating Amps
120V 208V 240V 277V
Input
Watts
LAMP
ANSI
Initial
Lumens
Lamp
Hours
Lamp supplied with fixture
150 ED17 Medium HX-HPF QT 1.3/1.6 1.0/1.0 .7/.8 .6/.7 185 M102 14000 15000
Factory Installed Options
Add suffix to Catalog Number
Swivel Photocontrol wired for 120V (/PCS)
Single fusing for 120 and 277 volt (/F)
Double fusing for 208 and 240 volt (/FF)
Button Photocontrol wired for 120V (/PC)
RAB Lighting, Inc. • 170 Ludlow Ave• Northvale, NJ 07647 • Tel: 888 RAB-1000 • Fax: 888 RAB-1232 • www.rabweb.com
© 2009
Note: Specifications may change without notice

Summary of content (1 pages)