STEALTH STL110 Installation Manual STL110 STL110HB STL110H STL110R Specifications: Switching Capacity: 8 amps Voltage: 120 volts 1000 watts Incandescent 500 watts Fluorescent Detection Pattern: 50’ x 110˚ Time Adjustment: 5 seconds to 12 minutes Power Consumption: 1 watt Surge protection: I. E.C.
Cautions: Mounting Plate: TURN OFF ALL POWER AT CIRCUIT BREAKER/FUSE PANEL. STL110 floodlight kits come prewired and assembled on the RAB CU4 EZ plate, allowing for mounting on round, rectangular or octagonal surface or recessed boxes. Read entire Installation Manual before proceeding. All wiring should comply with local electrical codes and requires a qualified electrician. The total lighting load connected to Stealth must not exceed 8 amps (1000 watts incandescent or quartz, 500 watts fluorescent).
How Does the STEALTH Work? Stealth’s infrared sensor “sees” small temperature changes caused by the motion of people or cars within its protection zone and turns on lights automatically. It welcomes visitors and may deter intruders. How long do the lights stay on? Lights remain on as long as there is movement within the protection zone. Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes.
Picking a Location Choose a location from which the sensor can “see” all the paths of movement. The sensor may be wall or ceiling mounted. As distance from the sensor increases, it will take more movement to be detected. For instance, at 10 feet, a half step will be enough, while at 40 feet several steps will be necessary. How does the LED Detection Indicator work? The red LED above the lens shows the logic state of the sensor.
Kit Wiring EZ Plate Red pigtail is only used to switch remote or additional fixtures. 1. Attach the Universal Mounting bar with the bar screws (provided) to the junction box. If you are attaching your STL110 kit to a surface mount weatherproof box, you must use both gaskets, with the metal mounting plate Metal Mounting Plate Bar Screws CU4 EZ Plate Insert close-up plug in unused hole 4. Strip 1/2" of insulation from all leads. 5. Attach ground wire(s) to junction box grounding screw.
Wiring Diagrams White Basic Wiring Diagram Power In Red Black Sensor Red (pigtail) Basic Kit Wiring Note: Pigtail is only used to switch remote or additional light fixtures Power In Red Black White Ground White Ground White Multiple Fixtures Power in Black Red Multiple (pigtail) fixtures may be wired to a single sensor. Power In Black Ground Red .1uF 400v DC capacitor Relay rated to handle load required Switchplate Label Switchplate label with self-adhesive backing.
Aiming And Walk Testing Animal Alley Walk Test The purpose of the Walk Test is to check and adjust the coverage pattern. Stealth has a 5 minute Test Period which allows the sensor to be aimed and walk tested day or night. If you require 5 more minutes of Test Time, turn the power off for at least 10 seconds and back on again. During the Test Period, the sensor will keep lights on for 5 seconds each time it detects movement in its Detection Zone.
Technical Tips: Lights Do Not Turn Off 1. Make sure that the sensor is not in Manual Override Mode. Turn power OFF for 10 seconds, then ON Sensor will be in Test Mode for approximately 5 minutes, then it will switch to Auto Mode with lights off and ready to detect movement. 2. Make sure sensor is not aimed at or mounted over something that would move or change temperature such as waving branches, water, air conditioners, windows or heating vents—even on neighboring property.
Technical Tips: Lights Turn On and Off Inappropriately 1. Make sure the sensor is installed on its own dedicated circuit, free of motor loads such as HVAC equipment, kitchen appliances or garage door openers. 2. It is not recommended to wire sensors in parallel. More than one sensor wired together makes them difficult to troubleshoot. Disconnect multiple sensors and test separately. 3. Keep all people completely out of the detection pattern to make sure the sensor is not detecting them. 4.
Technical Tips: Lights Do Not Turn On 1. Check that lamps and fixtures work. Compare wiring to the wiring diagram in this manual. Check that the power is on. 2. If installing during daylight, remember that the sensor will provide 5 minutes of Test Time after power is turned on. After 5 minutes, the sensor will switch to Automatic Mode and will not work during daylight if the photocell control is turned to the night only position (moon symbol). Lights Turn Off Too Quickly 1.
Technical Tips: Range Appears Limited 1. Check that the sensor is level from side to side and pointed at the area you desire. If unit is tilted, part of the detection zone may be high in the air over people’s heads. 3. Check that movement is not directly towards sensor. Sensor will see movement across its pattern more quickly. To fix, move the sensor. WRONG! Less Sensitive Solution: Position sensor exactly level from side to side. More Sensitive OK! 2. Check that the sensor is not mounted too high.
Technical Tips: Lights Turn On for Unknown Reasons 1. Lights may turn on occasionally during rain, snow and windstorms because the sensor is detection changes in temperature. Solution: Mount sensor in protected area. 3. You may not be aware that animals have triggered the sensor. Check sensor aiming to reduce nuisance triggering or mask the lower part of the lens with opaque weatherproof tape to create an “Animal Alley”. 10’ This is the “Animal Alley” 50’ 4.
Limited Warranty Your Stealth will be replaced or repaired, at our option, if it proves to be defective in workmanship or materials within ten years from the date of original purchase. For repair replacement, return the product freight prepaid and insured to: RAB Lighting 170 Ludlow Avenue Northvale, NJ 07647 The Stealth should be packed carefully. Please include you sales receipt and a description of the problem.
Contents of Accessory Kit • Indoor Switchplate Label • 3 Wire Nuts • Crossbar with Green Ground Screw • Hanging Hook • 1/2" Close Up Plugs (3) • Slotted Screws (4) • Finishing Cap • O-ring Gasket • Center Mounting Screw • Foam Gaskets (2) • Metal Plate 13
Easy Installation & Product Help Toll Free Phone Call our friendly experts. 8AM - 6PM ET Mon. - Fri. 888 RAB-1000 Toll Free Fax Send faxes to RAB 24/7. 888 RAB-1232 E-mail Questions and requests answered promptly tech@rabweb.com www.rabweb.com Visit our internet site for product information RAB Lighting 170 Ludlow Avenue Northvale, New Jersey 07647 U.S.A. © RAB Lighting 2004 Fax on Demand Faxed information, 24/7.