Alarms Acknowledge
Fig. 7.16: Menu Link settings Alarms Acknowledge
Alarm acknowledgement is a way to allow the operator to confirm the system is in alarm state. Only
an active alarm can be acknowledged.
Multiple selection of active alarms (to acknowledge groups of alarms) can be performed using Shift or
Ctrl keys.
Alarm identification. The following alarms can appear:
Inside temperature, Voltage min, Voltage max, RSS, SNR, BER, Net bitrate, Air
link, Eth1 link, Eth2 link, RF power
Name
There are three possible alarm states:
OK ... No alarm (alarm is inactive) or alarm disabled.
Ack ... Alarm is active and acknowledged.
Alarm ... Alarm is active and is not acknowledged.
State
Time stamp when the alarm occured.From
Time stamp when the alarm expired (returned to normal conditions).To
Time stamp when the alarm was acknowledged.
Time stamp format: yyyy-MM-dd hh:mm:ss
Ack
Name (login) of the user who acknowledged the alarm.User
The comment field can be used to add user defined comments when 'alarm ac-
knowledge' is performed. Use this comment to describe important details of the
Comment
alarm status. The comment can be up to 50 characters long. Special characters
are not allowed.
The alarm can be acknowledged multiple times with different comments. Every
acknowledgement is written to the internal memory and is visible in the alarm log.
RAy2 Microwave Link © RACOM s.r.o.82