User's Manual
Table Of Contents
- RipEX2 Radio modem & Router
- Table of Contents
- Important Notice
- 1. Quick guide
- 2. Product
- 3. Accessories
- 4. Installation
- 5. RipEX2 in detail
- 6. Web interface
- 7. Settings
- 7.1. Interfaces
- 7.1.1. Ethernet
- 7.1.2. Radio
- 7.1.3. COM
- 7.1.4. Terminal servers
- 7.1.5. Cellular
- 7.2. Routing
- 7.2.1. Static
- 7.2.2. OSPF
- 7.2.2.1. Description
- 7.2.2.2. Common - Common settings
- 7.2.2.3. Network - Areas and interfaces - Areas
- 7.2.2.4. Network - Areas and interfaces - Interfaces
- 7.2.2.5. Network - Areas and interfaces - Neighbors
- 7.2.2.6. Network - Areas and interfaces - Networks
- 7.2.2.7. Static rules
- 7.2.2.8. Import filter
- 7.2.2.9. Export filter
- 7.2.3. BGP
- 7.3. Firewall
- 7.4. VPN
- 7.5. Security
- 7.6. Device
- 7.7. Advanced
- 7.1. Interfaces
- 8. Diagnostics
- 9. Technical parameters
- 10. Safety, regulations, warranty
- 10.1. Frequency
- 10.2. Safety distance
- 10.3. High temperature
- 10.4. Battery disposal
- 10.5. Instructions for Safe Operation of Equipment
- 10.6. SW license
- 10.7. EU Compliance
- 10.8. Compliance Federal Communications Commission and Innovation, Science and Economic Development Canada
- 10.9. Compliance ANATEL Brasil
- 10.10. Warranty
- 10.11. RipEX2 Availability and service life time
- 10.12. RipEX2 maintenance
- Appendix A. Abbreviations
- Index
- Revision History
RipEX2 can be equipped with an internal GPS (Expansion board 'G'). The GPS module is used for
time synchronization of the NTP server inside RipEX2. In this case the AUX connector serves for
connecting the GPS antenna:
• active antenna
•
3.3 VDC supply see details
2.2.8. DI/DO
Tab. 2.6: Digital Inputs and Outputs
SignalDescriptionPin
Digital input (differential) - Positive - (P)DI1+1
Digital input (differential) - Negative - (N)DI1-2
GroundGND3
Digital Output 1DO14
Digital Output 2DO25
GroundGND6
Digital Input 2DI27
Digital Input 3DI38
• Digital Outputs:
○ Open drain output max. 30 VDC, 0.2 A
• Isolated differential digital input:
○ Input voltage difference (P-N) > 1.9 VDC Logic "H"
○ Input voltage difference (P-N) < 1.1 VDC Logic "L"
○ Maximum differential voltage 30 V
• Digital inputs:
○ Schmitt-triggered inverted input
○ Pull below 1.1 VDC to activate (1.1 VDC / 1.9 VDC threshold hysteresis)
○ Max. 30 VDC
If the RipEX2 unit is installed in the RipEX2-HS (Hot Standby chassis), the DI/DO interface is dedicated
for the Hot Standby operation.