User's Manual

Table Of Contents
Tab. 2.7: Key to LEDs
FunctionStyleColourLED
System OKPermanently lit
Green
SYS
Reset button pushedFlashing - period 500 ms
Reset button factory reset
Three fast (50 ms) flashes - pause
(500 ms)
AlarmPermanently lit
Red
Serious system errorFlashing regularly - period 500 ms
Unit is startingPermanently litOrange
Activity of mPCIe connected equipent
(like GPS fix, LTE connected, ...)
Permanently litGreen
AUX
Alarm of mPCIe connected equipmentPermanently litRed
Receiver is synchronized to a packetPermanently litGreen
Rx
Rx mode of operation - high resistance
(strong interfering signals - above -45
Permanently lit, or flashing in 1 sec
intervals
Yellow dBm - are present within the frequency
band), adaptive mode of receiver oper-
ation
Transmitting to radio channelPermanently litRedTx
Data receivingPermanently litGreen
COM
Data transmittingPermanently litYellow
Alarm An Alarm is triggered by any event with severity Error or higher (see
Section 8.2, “Events”).
Adaptive mode of receiver opera-
tion
Cognitive function of receiving mode selection is implemented in
RipEX2. When exposed in a radio environment where strong inter-
fering signals (stronger than -45 dBm) are present, RipEX2 senses
them and adaptively increases its resistance to interference (and
lowers its sensitivity by 3 dB). When interference holds, RipEX2
stays in high resistance mode of receiver operation and signals this
state by turning the yellow RX LED on. Once the interfering signals
fade away, RipEX2 automatically returns to its high sensitivity mode
of receiver operation.
23© RACOM s.r.o. RipEX2 Radio modem & Router