Specifications
Quick Start Guide  ASMi-52L Installation and Operation Manual 
2 Configuring ASMi-52L   
Configuring the Master Clock 
 
To configure the master clock: 
•  From the System Configuration menu (Main menu > Configuration > 
System Configuration > Master Clock), configure the central ASMi-52L clock 
to external or internal and remote ASMi-52L clock to the receive clock. 
Configuring the SHDSL Interface 
 
To configure the SHDSL interface: 
•  From the SHDSL Configuration menu (Main menu > Configuration > Port 
Configuration > SHDSL Configuration), configure the following SHDSL 
parameters: 
  SHDSL compatibility 
  Power backoff 
  Snext margin, if line probing is set to adaptive 
  Current margin, if line probing is set to adaptive 
  Power spectral density (for ASMi-52L with 2-wire line interface and line 
probing set to fixed). 
  Line probing 
  Line type (for 4-wire ASMi-52L units only) 
  Loop attenuation threshold 
  SNR margin threshold. 
Configuring the DTE Interface 
ASMi-52L includes a serial or 10/100BaseT DTE interface. 
Configuring the Serial Interface 
 
To configure the serial interface: 
•  From the DTE Port Configuration (Main menu > Configuration > Port 
Configuration > DTE Configuration), select the required data rate. 
Configuring the 10/100BaseT Interface 
 
To configure 10/100BaseT parameters: 
1.  From the LAN Configuration menu (Main menu > Configuration > LAN 
Configuration), configure the following LAN parameters: 
  Operation mode 
  Bridge static table 
  Aging timeout 
  LAN rate. 
For units with the four port integrated switch, configure the parameters one time. 
2.  Configure the Autonegotiation per port 
3.  Configure the Max Advertised Capability per port. 