ASMi-52L Installation and Operation Manual  Chapter 6 Troubleshooting and Diagnostics 
  Monitoring Performance  6-3 
ASMi-52L 
SHDSL current day performance 
  Local  Remote 
24 hour ES  (0)  (0) 
24 hour UAS  (0)  (0) 
24 hour SES  (0)  (0) 
24 hour LOWS  (0)  (0) 
24 hour CRC  (0)  (0) 
Cur. Day Timer  (10 hour)  (10 hour) 
Day Intervals  (10)  (10) 
ESC-prev.menu; !-main menu; &-exit; @-scroll 
Figure 6-4. SHDSL current day Performance Screen 
Table 6-1. SHDSL Statistics Parameters 
Display Description 
Current ES  Number of errored seconds in which one or more CRC (Cyclic Redundancy Check) 
error events occurred during the current interval. This value is updated every second. 
Current UAS  Number of unavailable seconds in which a failed signal occurred during the current 
interval. This value is updated every second. 
Current SES  Number of severely errored seconds in which 832 or more CRC error events occurred 
during the current interval. This value is updated every second. 
Current LOSWS  Number of seconds with loss of sync word during the current interval. This value is 
updated every second. 
Current CRC 
anomalies 
Number of CRC error events recorded since the last time the register was cleared. 
Current TIMER  Time in seconds from the beginning of the interval. This value is updated every second. 
Displaying the SHDSL Statistics for all Intervals 
You can display detailed SHDSL performance statistics for 96 last 15-minute 
intervals or seven last day (24 hour) intervals elapsed since the last power-up. 
 
To display the SHDSL statistics for all intervals: 
1.  From the SHDSL Statistics menu (see Figure 6-2), select SHDSL All Intervals 
Performances to display the SHDSL statistics for 15-minute intervals or select 
SHDSL All Days Performances to display the SHDSL statistics for day 
intervals. 
The SHDSL All Intervals screen appears (see Figure 6-3 and 
Figure 6-4). 
2.  Press any key to return to the SHDSL Statistics menu. 