Specifications
ASMi-52L Installation and Operation Manual  Chapter 6 Troubleshooting and Diagnostics 
  Testing ASMi-52L  6-13 
The Diagnostics menu is displayed (see Figure 6-12). 
2.  From the Diagnostics menu, select: 
 Local Test to run the LLB on the local ASMi-52L 
 Remote Test to run the LLB on the remote ASMi-52L. 
The Local/Remote Test menu appears (see Figure 6-13). 
3. Select LLB. 
The LLB value in parenthesis changes to ON. Also, an additional 
parameter, Loop Timeout, is displayed for the local ASMi-52L. 
4. Select Loop Timeout, if you want to set loopback timeout (in minutes). 
The Loop Timeout value changes. 
Avoid setting timeout to 0 as local control is lost during LLB. 0=Forever 
5.  Once you selected the loopback timeout, select Save to activate the LLB. 
The LLB is initiated. The TST indicator lights up and the ASMi-52L units 
lose synchronization. 
ASMi-52L 
Diagnostics 
1. Local Test  > 
2. Remote Test  > 
3. Repeater Test  > 
> 
ESC-previous menu ; !–main menu ; &–exit terminal 
Figure 6-12. Diagnostics Menu 
ASMi-52L 
Local Test or Remote Test 
LLB from DTE: OFF 
RLB from DTE: OFF 
1. LLB (ON) 
2. Loop Timeout (min)(0-4095) ...(5) 
3. LEDs test 
4. Clear all 
5. Save 
> 
ESC-previous menu ; !–main menu ; &–exit; @-scroll 
Figure 6-13. Local/Remote Test Menu 
Note 